- Maximum load current: 11 A (continuous) or 13 A (up to 5 sec)
- Up to 1000m in an open space (in a perfect environment)
- Executes scenarios
- Relay: NO/NC
- Pulse duration: 0.5 - 255 sec
- Operating frequencies - 868.0 - 868.6 MHz
- Operating voltage: 110 - 230 VAC
- Output power: up to 2.5 kW
- Dimensions: 65.5 × 45 × 45 mm
Manufacturer overview
Smart plug with power consumption monitoring
Control appliances remotely. You will come back home to enjoy comfortable climate and cozy atmosphere all year round. Turn on your heating devices during winter and air conditioner during summer. Start your humidifier and heat water for your bath: do it all with only a few taps in the app on your way home.
Monitor power consumption. You will come back home to enjoy comfortable climate and cozy atmosphere all year round. Turn on your heating devices during winter and air conditioner during summer. Start your humidifier and heat water for your bath: do it all with only a few taps in the app on your way home.
Automate your security. You will come back home to enjoy comfortable climate and cozy atmosphere all year round. Turn on your heating devices during winter and air conditioner during summer. Start your humidifier and heat water for your bath: do it all with only a few taps in the app on your way home.
Everything is ready by the time you get home. You will come back home to enjoy comfortable climate and cozy atmosphere all year round. Turn on your heating devices during winter and air conditioner during summer. Start your humidifier and heat water for your bath: do it all with only a few taps in the app on your way home.
No more worries about forgetting an iron on. When you leave your house, close the door and arm the system. All top energy consuming and dangerous appliances will be automatically switched off. Iron, heater, and toaster will no longer create a risk of fire.
Identifies power vampires. Socket informs you about the most power consuming devices. As soon as an appliance starts consuming electricity, Socket's LED changes colour in real time.
Specifications
| Power supply voltage |
110–230 V~, 50/60 Hz |
| Maximum continuous load current |
11 A |
| Output power |
up to 2.5 kW (resistive load at 230 V~) |
| Average consumption |
up to 1 W |
| Current protection |
more than 11 A (when Current protection is enabled) |
| Voltage protection for 230 V~ mains electricity |
min — 184 V~ |
| Voltage protection for 110 V~ mains electricity |
min — 88 V~ |
| Electric shock protection class |
Class I (with grounding terminal) |
| Frequency bands |
866.0–866.5 MHz 868.0–868.6 MHz 868.7–869.2 MHz 905.0–926.5 MHz 915.85–926.5 MHz 921.0–922.0 MHz |
| Maximum effective radiated power (ERP) |
up to 25 mW |
| Radio signal modulation |
GFSK |
| Radio communication range |
up to 3,300 ft |
| Adjustable pulse duration 2 |
from 1 to 255 s |
| Protection against spoofing |
device authentication |
| Communication loss detection |
after 36 s |
| Protection class |
IP20 |
| Temperature protection |
more than 185 °F |
| Dimensions |
1.77" × 1.77" × 2.74" |
| Weight |
2.05 oz |
| Operating temperature range |
from 32 °F to 104 °F |
| Operating humidity |
up to 75% with no condensation |
| Warranty |