- Smoke-sensitive element: Photoelectric sensor
- Temperature-sensitive element: Thermocouple
- Volume of built-in siren: 85 dB
- Power supply: Battery - 2 x CR2 batteries, 3 V, Backup battery - CR2032
- Battery life: up to 4 years
- Up to 1300m in an open space (in a perfect environment)
- Certification: EN 14604
- Dimensions: 132 × 132 × 31 mm
Manufacturer overview
Wireless fire detector with temperature sensor that monitors security in the room twenty four hours a day and immediately notifies of smoke and sharp jumps in temperature.
Principle of operation. The device detects smoke by means of a camera with photoelectric sensor. If no smoke is emitted, the additional detector registers temperature increase in the room.
Features. It can operate independently from the hub, emitting a fire alarm through a built-in siren. When added to a hub, the detector supports interconnected fire alarms, allowing several detectors to indicate an alarm simultaneously.
Installation and set up. Ready to operate straight out the box: the battery is already installed, therefore there is no need to disassemble the detector. With one click, it can be connected to the hub in the mobile application. It can be mounted on the SmartBracket in just a few minutes.
Ajax product categories. In an Ajax system, you can combine devices of all product categories: Intrusion protection, Video surveillance, Fire and life safety, or Comfort and automation. Create the system to suit your needs and manage it in a single interface.
What is a wireless fire sensor. Wireless smoke detector is an element of the fire safety system that detects the signs of a fire and sends danger signals to a burglar alarm or to other security system users. The installation of a fire alarm sensor makes it possible to prevent the spread of fire in time.
Ajax FireProtect wireless fire detection sensor. A wireless fire detector will provide round-the-clock fire safety monitoring in the room. The Ajax FireProtect instantly reports smoke and sudden temperature jumps.
Specifications
| Frequency bands |
866.0 – 866.5 MHz 868.0 – 868.6 MHz 868.7 – 869.2 MHz 905.0 – 926.5 MHz 915.85 – 926.5 MHz 921.0 – 922.0 MHz |
| Maximum effective radiated power (ERP) |
up to 20 mW |
| Radio signal modulation |
GFSK |
| Radio communication range |
up to 4,200 ft |
| Sensitive element |
photoelectric sensor |
| Built-in siren |
85 dB volume at a distance of 9 ft |
| Protection against spoofing |
device authentication |
| Communication loss detection |
after 36 s |
| Batteries |
2 × CR2 (pre-installed) |
| Protection class |
IP40 |
| High temperature alarm |
at temperatures above 140 °F |
| Temperature spike alarm |
when the temperature rises more than 86 °F in 30 minutes or less |
| Dimensions |
5.2″ × 5.2″ × 1.22″ |
| Weight |
7.76 oz |
| Operating temperature range |
from 32 °F to 149 °F |
| Operating humidity |
up to 80% |
| Warranty |
24 months |