{"product_id":"linkqnet-lifepo4-512v-100ah-rackmount-battery-pack-with-can-bms","title":"LINKQNET LIFEPO4 51.2V 100AH RACKMOUNT BATTERY PACK WITH CAN BMS","description":"\u003ch4\u003eFeatures\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eHigh Density Solution: The battery pack is expertly constructed from premium materials and complies with all major safety and performance SPECIFICATIONS\u003c\/li\u003e\n\u003cli\u003eThe core cell storage consists of sixteen new Lithium-Ion Phosphate (LFP) prismatic cells manufactured by Hefei Guoxuan Hi-Tech Power Energy Co., Ltd\u003c\/li\u003e\n\u003cli\u003eGuoxuan are the manufacturers of choice for leading German EV brands and well as many other electric vehicle manufacturers\u003c\/li\u003e\n\u003cli\u003eInnovative Battery Management System: The BMS has been designed with the experience of over ten years of battery management involvement\u003c\/li\u003e\n\u003cli\u003eIt uses internationally sourced components to ensure consistency, performance and reliability\u003c\/li\u003e\n\u003cli\u003eThe firmware is interactively developed and robust\u003c\/li\u003e\n\u003cli\u003eThe flexibility of both CAN bus and RS485 communications allows for a wide range of applications\u003c\/li\u003e\n\u003cli\u003eThe LCD display allows a clear overview of the battery state of charge and condition without the need for interfacing to a computer\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003ch4\u003eBasic Parameters\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eRated Voltage: 51.2 Volts\u003c\/li\u003e\n\u003cli\u003eRated Capacity: 100 Amp Hours\u003c\/li\u003e\n\u003cli\u003eRated Energy: 5120 Watt Hours\u003c\/li\u003e\n\u003cli\u003eRating: 1C\u003c\/li\u003e\n\u003cli\u003e\n\u003cli\u003eOPERATING PARAMETERS\u003c\/li\u003e\n\u003cli\u003eOperating Voltage Range: 44.8 Volts - 56.0 Volts\u003c\/li\u003e\n\u003cli\u003eCharge Voltage Range: 55.2 Volts - 56.0 Volts (Typical Inverter Bulk\/Float Charge can be set to 55.3V)\u003c\/li\u003e\n\u003cli\u003eCut-Oﬀ Voltage: 44.8 Volts (Typical Inverter Cut Oﬀ can be set to 46.0V)\u003c\/li\u003e\n\u003cli\u003eRecommended Charge Current: 50 Amps\u003c\/li\u003e\n\u003cli\u003eMaximum Charge Current: 100 Amps\u003c\/li\u003e\n\u003cli\u003eMaximum Discharge Current: 100 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cli\u003ePHYSICAL PARAMETERS\u003c\/li\u003e\n\u003cli\u003eDimensions: 442mm (D) x 470mm (W) x 154mm (3.5U - high)\u003c\/li\u003e\n\u003cli\u003eWeight: 46kg\u003c\/li\u003e\n\u003cli\u003eCommunication Ports: RS485 (For programming) , CAN bus, 2x Inverter Battery-Comm \/ Stacking Ports\u003c\/li\u003e\n\u003cli\u003eDisplay: LED and LCD with cursor keys for BMS Status and State of Charge\u003c\/li\u003e\n\u003cli\u003eOutput Terminal: 2x M6 Bolts for Positive, 2x M6 Bolts for Negative\u003c\/li\u003e\n\u003cli\u003eOutput Protection: Internal Electronic Circuit Disconnecter, 125 Amp DC Circuit Breaker\u003c\/li\u003e\n\u003cli\u003e\n\u003cli\u003eENVIRONMENTAL\u003c\/li\u003e\n\u003cli\u003eHumidity: 5% - 95% Relative Humidity\u003c\/li\u003e\n\u003cli\u003eCharge Temperature Range: 0°C to 45°C\u003c\/li\u003e\n\u003cli\u003eDischarge Temperature Range: -20°C to 60°C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature Range: -20°C to 45°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cli\u003eSERVICE LIFE\u003c\/li\u003e\n\u003cli\u003eCycle Life: More than 6000 Cycles at 50 Amp Discharge Rate and 80% Depth of Discharge\u003c\/li\u003e\n\u003cli\u003eHardware Design Life: Fifteen Years\u003c\/li\u003e\n\u003cli\u003eWarranty: Five Years, based on the terms and conditions of the warranty policy\u003c\/li\u003e\n\u003cli\u003e\n\u003cli\u003eCERTIFICATION\u003c\/li\u003e\n\u003cli\u003eSafety: CE, EMC, TUV (IEC62619), UL1973\u003c\/li\u003e\n\u003cli\u003eTransportation: UN38.3\u003c\/li\u003e\n\u003cli\u003e\n\u003cli\u003eINSTALLATION\u003c\/li\u003e\n\u003cli\u003eInverter Integration to BMS: Requires customised cable for each speciﬁc inverter brand, refer to manual\u003c\/li\u003e\n\u003cli\u003eInverter Integration without BMS: Will emulate Lead Acid battery, can be optimised by altering inverter parameters\u003c\/li\u003e\n\u003cli\u003eBMS base protocol compatibility: Voltronic “LIb\" BMS protocol \/ Optional Pylontech BMS protocol\u003c\/li\u003e\n\u003cli\u003eAddressable Parallel Stacking: Battery packs can be paralleled up to sixteen addressable units per solution\u003c\/li\u003e\n\u003cli\u003eInstallation Competency: Not consumer installable. Needs to be wired into inverter\/UPS by a qualiﬁed electrical contractor with appropriate experience.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eShipping Dimensions\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eWeight: 48.00 kg\u003c\/li\u003e\u003c\/ul\u003e","brand":"Linkqage","offers":[{"title":"Default Title","offer_id":51284260290845,"sku":"BAT-LI-5120-TG","price":35640.0,"currency_code":"ZAR","in_stock":true}],"url":"https:\/\/gdtechnologies.co.za\/products\/linkqnet-lifepo4-512v-100ah-rackmount-battery-pack-with-can-bms","provider":"GD TECHNOLOGIES","version":"1.0","type":"link"}